authorGregory P. Smith <greg@krypto.org>2014-06-01 20:22:12 (GMT)
committerGregory P. Smith <greg@krypto.org>2014-06-01 20:22:12 (GMT)
commit3fe9e8d5a5ff730b3497fc4e5361bf15ccac14bb (patch)
treecf2e620b22bf132035b4a63cacac6b590ab84c0a /Modules
parent3ffa7ab2ef856b24f606273b08c5536c4dd12198 (diff)
parentd4dcb70287c7716b8d75014512070a0ad5c7740f (diff)
downloadcpython-3fe9e8d5a5ff730b3497fc4e5361bf15ccac14bb.zip
cpython-3fe9e8d5a5ff730b3497fc4e5361bf15ccac14bb.tar.gz
cpython-3fe9e8d5a5ff730b3497fc4e5361bf15ccac14bb.tar.bz2
Don't restrict ourselves to a "max" fd when closing fds before exec()
when we have a way to get an actual list of all open fds from the OS. Fixes issue #21618: The subprocess module would ignore fds that were inherited by the calling process and already higher than POSIX resource limits would otherwise allow. On systems with a functioning /proc/self/fd or /dev/fd interface the max is now ignored and all fds are closed.
Diffstat (limited to 'Modules')
-rw-r--r--Modules/_posixsubprocess.c87
1 files changed, 44 insertions, 43 deletions
diff --git a/Modules/_posixsubprocess.c b/Modules/_posixsubprocess.c
index 648a569..8f5ce04 100644
--- a/Modules/_posixsubprocess.c
+++ b/Modules/_posixsubprocess.c
@@ -44,10 +44,6 @@
#define POSIX_CALL(call) do { if ((call) == -1) goto error; } while (0)
-/* Maximum file descriptor, initialized on module load. */
-static long max_fd;
-
-
/* Given the gc module call gc.enable() and return 0 on success. */
static int
_enable_gc(PyObject *gc_module)
@@ -166,14 +162,39 @@ make_inheritable(PyObject *py_fds_to_keep, int errpipe_write)
}
-/* Close all file descriptors in the range start_fd inclusive to
- * end_fd exclusive except for those in py_fds_to_keep. If the
- * range defined by [start_fd, end_fd) is large this will take a
- * long time as it calls close() on EVERY possible fd.
+/* Get the maximum file descriptor that could be opened by this process.
+ * This function is async signal safe for use between fork() and exec().
+ */
+static long
+safe_get_max_fd(void)
+{
+ long local_max_fd;
+#if defined(__NetBSD__)
+ local_max_fd = fcntl(0, F_MAXFD);
+ if (local_max_fd >= 0)
+ return local_max_fd;
+#endif
+#ifdef _SC_OPEN_MAX
+ local_max_fd = sysconf(_SC_OPEN_MAX);
+ if (local_max_fd == -1)
+#endif
+ local_max_fd = 256; /* Matches legacy Lib/subprocess.py behavior. */
+ return local_max_fd;
+}
+
+
+/* Close all file descriptors in the range from start_fd and higher
+ * except for those in py_fds_to_keep. If the range defined by
+ * [start_fd, safe_get_max_fd()) is large this will take a long
+ * time as it calls close() on EVERY possible fd.
+ *
+ * It isn't possible to know for sure what the max fd to go up to
+ * is for processes with the capability of raising their maximum.
*/
static void
-_close_fds_by_brute_force(int start_fd, int end_fd, PyObject *py_fds_to_keep)
+_close_fds_by_brute_force(long start_fd, PyObject *py_fds_to_keep)
{
+ long end_fd = safe_get_max_fd();
Py_ssize_t num_fds_to_keep = PySequence_Length(py_fds_to_keep);
Py_ssize_t keep_seq_idx;
int fd_num;
@@ -229,16 +250,14 @@ struct linux_dirent64 {
* it with some cpp #define magic to work on other OSes as well if you want.
*/
static void
-_close_open_fd_range_safe(int start_fd, int end_fd, PyObject* py_fds_to_keep)
+_close_open_fds_safe(int start_fd, PyObject* py_fds_to_keep)
{
int fd_dir_fd;
- if (start_fd >= end_fd)
- return;
fd_dir_fd = _Py_open(FD_DIR, O_RDONLY);
if (fd_dir_fd == -1) {
/* No way to get a list of open fds. */
- _close_fds_by_brute_force(start_fd, end_fd, py_fds_to_keep);
+ _close_fds_by_brute_force(start_fd, py_fds_to_keep);
return;
} else {
char buffer[sizeof(struct linux_dirent64)];
@@ -253,23 +272,23 @@ _close_open_fd_range_safe(int start_fd, int end_fd, PyObject* py_fds_to_keep)
entry = (struct linux_dirent64 *)(buffer + offset);
if ((fd = _pos_int_from_ascii(entry->d_name)) < 0)
continue; /* Not a number. */
- if (fd != fd_dir_fd && fd >= start_fd && fd < end_fd &&
+ if (fd != fd_dir_fd && fd >= start_fd &&
!_is_fd_in_sorted_fd_sequence(fd, py_fds_to_keep)) {
while (close(fd) < 0 && errno == EINTR);
}
}
}
- close(fd_dir_fd);
+ while (close(fd_dir_fd) < 0 && errno == EINTR);
}
}
-#define _close_open_fd_range _close_open_fd_range_safe
+#define _close_open_fds _close_open_fds_safe
#else /* NOT (defined(__linux__) && defined(HAVE_SYS_SYSCALL_H)) */
-/* Close all open file descriptors in the range start_fd inclusive to end_fd
- * exclusive. Do not close any in the sorted py_fds_to_keep list.
+/* Close all open file descriptors from start_fd and higher.
+ * Do not close any in the sorted py_fds_to_keep list.
*
* This function violates the strict use of async signal safe functions. :(
* It calls opendir(), readdir() and closedir(). Of these, the one most
@@ -282,17 +301,13 @@ _close_open_fd_range_safe(int start_fd, int end_fd, PyObject* py_fds_to_keep)
* http://womble.decadent.org.uk/readdir_r-advisory.html
*/
static void
-_close_open_fd_range_maybe_unsafe(int start_fd, int end_fd,
- PyObject* py_fds_to_keep)
+_close_open_fds_maybe_unsafe(long start_fd, PyObject* py_fds_to_keep)
{
DIR *proc_fd_dir;
#ifndef HAVE_DIRFD
- while (_is_fd_in_sorted_fd_sequence(start_fd, py_fds_to_keep) &&
- (start_fd < end_fd)) {
+ while (_is_fd_in_sorted_fd_sequence(start_fd, py_fds_to_keep)) {
++start_fd;
}
- if (start_fd >= end_fd)
- return;
/* Close our lowest fd before we call opendir so that it is likely to
* reuse that fd otherwise we might close opendir's file descriptor in
* our loop. This trick assumes that fd's are allocated on a lowest
@@ -300,8 +315,6 @@ _close_open_fd_range_maybe_unsafe(int start_fd, int end_fd,
while (close(start_fd) < 0 && errno == EINTR);
++start_fd;
#endif
- if (start_fd >= end_fd)
- return;
#if defined(__FreeBSD__)
if (!_is_fdescfs_mounted_on_dev_fd())
@@ -311,7 +324,7 @@ _close_open_fd_range_maybe_unsafe(int start_fd, int end_fd,
proc_fd_dir = opendir(FD_DIR);
if (!proc_fd_dir) {
/* No way to get a list of open fds. */
- _close_fds_by_brute_force(start_fd, end_fd, py_fds_to_keep);
+ _close_fds_by_brute_force(start_fd, py_fds_to_keep);
} else {
struct dirent *dir_entry;
#ifdef HAVE_DIRFD
@@ -324,7 +337,7 @@ _close_open_fd_range_maybe_unsafe(int start_fd, int end_fd,
int fd;
if ((fd = _pos_int_from_ascii(dir_entry->d_name)) < 0)
continue; /* Not a number. */
- if (fd != fd_used_by_opendir && fd >= start_fd && fd < end_fd &&
+ if (fd != fd_used_by_opendir && fd >= start_fd &&
!_is_fd_in_sorted_fd_sequence(fd, py_fds_to_keep)) {
while (close(fd) < 0 && errno == EINTR);
}
@@ -332,13 +345,13 @@ _close_open_fd_range_maybe_unsafe(int start_fd, int end_fd,
}
if (errno) {
/* readdir error, revert behavior. Highly Unlikely. */
- _close_fds_by_brute_force(start_fd, end_fd, py_fds_to_keep);
+ _close_fds_by_brute_force(start_fd, py_fds_to_keep);
}
closedir(proc_fd_dir);
}
}
-#define _close_open_fd_range _close_open_fd_range_maybe_unsafe
+#define _close_open_fds _close_open_fds_maybe_unsafe
#endif /* else NOT (defined(__linux__) && defined(HAVE_SYS_SYSCALL_H)) */
@@ -457,14 +470,8 @@ child_exec(char *const exec_array[],
/* close FDs after executing preexec_fn, which might open FDs */
if (close_fds) {
- int local_max_fd = max_fd;
-#if defined(__NetBSD__)
- local_max_fd = fcntl(0, F_MAXFD);
- if (local_max_fd < 0)
- local_max_fd = max_fd;
-#endif
/* TODO HP-UX could use pstat_getproc() if anyone cares about it. */
- _close_open_fd_range(3, local_max_fd, py_fds_to_keep);
+ _close_open_fds(3, py_fds_to_keep);
}
/* This loop matches the Lib/os.py _execvpe()'s PATH search when */
@@ -759,11 +766,5 @@ static struct PyModuleDef _posixsubprocessmodule = {
PyMODINIT_FUNC
PyInit__posixsubprocess(void)
{
-#ifdef _SC_OPEN_MAX
- max_fd = sysconf(_SC_OPEN_MAX);
- if (max_fd == -1)
-#endif
- max_fd = 256; /* Matches Lib/subprocess.py */
-
return PyModule_Create(&_posixsubprocessmodule);
}