diff options
-rw-r--r-- | Tools/msi/buildrelease.bat | 61 | ||||
-rw-r--r-- | Tools/msi/msi.props | 5 |
2 files changed, 57 insertions, 9 deletions
diff --git a/Tools/msi/buildrelease.bat b/Tools/msi/buildrelease.bat index ea25134..ca08df8 100644 --- a/Tools/msi/buildrelease.bat +++ b/Tools/msi/buildrelease.bat @@ -34,6 +34,7 @@ set BUILDX86= set BUILDX64=
set TARGET=Rebuild
set TESTTARGETDIR=
+set PGO=
:CheckOpts
@@ -52,6 +53,9 @@ if "%1" EQU "-b" (set TARGET=Build) && shift && goto CheckOpts if "%1" EQU "--build" (set TARGET=Build) && shift && goto CheckOpts
if "%1" EQU "-x86" (set BUILDX86=1) && shift && goto CheckOpts
if "%1" EQU "-x64" (set BUILDX64=1) && shift && goto CheckOpts
+if "%1" EQU "--pgo" (set PGO=%~2) && shift && shift && goto CheckOpts
+
+if "%1" NEQ "" echo Invalid option: "%1" && exit /B 1
if not defined BUILDX86 if not defined BUILDX64 (set BUILDX86=1) && (set BUILDX64=1)
@@ -81,7 +85,7 @@ if defined BUILDX86 ( )
if defined BUILDX64 (
- call :build x64
+ call :build x64 "%PGO%"
if errorlevel 1 exit /B
)
@@ -101,8 +105,15 @@ if "%1" EQU "x86" ( set BUILD_PLAT=Win32
set OUTDIR_PLAT=win32
set OBJDIR_PLAT=x86
-) ELSE (
- call "%PCBUILD%env.bat" x86_amd64
+) else if "%~2" NEQ "" (
+ call "%PCBUILD%env.bat" amd64
+ set PGO=%~2
+ set BUILD=%PCBUILD%amd64-pgo\
+ set BUILD_PLAT=x64
+ set OUTDIR_PLAT=amd64
+ set OBJDIR_PLAT=x64
+) else (
+ call "%PCBUILD%env.bat" amd64
set BUILD=%PCBUILD%amd64\
set BUILD_PLAT=x64
set OUTDIR_PLAT=amd64
@@ -128,17 +139,41 @@ if not "%CERTNAME%" EQU "" ( )
if not "%SKIPBUILD%" EQU "1" (
- call "%PCBUILD%build.bat" -e -p %BUILD_PLAT% -d -t %TARGET% %CERTOPTS%
- if errorlevel 1 exit /B
- call "%PCBUILD%build.bat" -e -p %BUILD_PLAT% -t %TARGET% %CERTOPTS%
- if errorlevel 1 exit /B
+ @call "%PCBUILD%build.bat" -e -p %BUILD_PLAT% -d -t %TARGET% %CERTOPTS%
+ @if errorlevel 1 exit /B
@rem build.bat turns echo back on, so we disable it again
@echo off
+
+ if "%PGO%" EQU "" (
+ @call "%PCBUILD%build.bat" -e -p %BUILD_PLAT% -t %TARGET% %CERTOPTS%
+ ) else (
+ @call "%PCBUILD%build.bat" -e -p %BUILD_PLAT% -c PGInstrument -t %TARGET% %CERTOPTS%
+ @if errorlevel 1 exit /B
+
+ @del "%BUILD%*.pgc"
+ if "%PGO%" EQU "default" (
+ "%BUILD%python.exe" -m test -q --pgo
+ ) else if "%PGO%" EQU "default2" (
+ "%BUILD%python.exe" -m test -r -q --pgo
+ "%BUILD%python.exe" -m test -r -q --pgo
+ ) else if "%PGO%" EQU "default10" (
+ for /L %%i in (0, 1, 9) do "%BUILD%python.exe" -m test -q -r --pgo
+ ) else if "%PGO%" EQU "pybench" (
+ "%BUILD%python.exe" "%PCBUILD%..\Tools\pybench\pybench.py"
+ ) else (
+ "%BUILD%python.exe" %PGO%
+ )
+
+ @call "%PCBUILD%build.bat" -e -p %BUILD_PLAT% -c PGUpdate -t %TARGET% %CERTOPTS%
+ )
+ @if errorlevel 1 exit /B
+ @echo off
)
"%BUILD%python.exe" "%D%get_wix.py"
set BUILDOPTS=/p:Platform=%1 /p:BuildForRelease=true /p:DownloadUrl=%DOWNLOAD_URL% /p:DownloadUrlBase=%DOWNLOAD_URL_BASE% /p:ReleaseUri=%RELEASE_URI%
+if "%PGO%" NEQ "" set BUILDOPTS=%BUILDOPTS% /p:PGOBuildPath=%BUILD%
msbuild "%D%bundle\releaselocal.wixproj" /t:Rebuild %BUILDOPTS% %CERTOPTS% /p:RebuildAll=true
if errorlevel 1 exit /B
msbuild "%D%bundle\releaseweb.wixproj" /t:Rebuild %BUILDOPTS% %CERTOPTS% /p:RebuildAll=false
@@ -158,7 +193,8 @@ exit /B 0 :Help
echo buildrelease.bat [--out DIR] [-x86] [-x64] [--certificate CERTNAME] [--build] [--skip-build]
-echo [--skip-doc] [--download DOWNLOAD URL] [--test TARGETDIR] [-h]
+echo [--pgo COMMAND] [--skip-doc] [--download DOWNLOAD URL] [--test TARGETDIR]
+echo [-h]
echo.
echo --out (-o) Specify an additional output directory for installers
echo -x86 Build x86 installers
@@ -166,6 +202,7 @@ echo -x64 Build x64 installers echo --build (-b) Incrementally build Python rather than rebuilding
echo --skip-build (-B) Do not build Python (just do the installers)
echo --skip-doc (-D) Do not build documentation
+echo --pgo Build x64 installers using PGO
echo --download Specify the full download URL for MSIs
echo --test Specify the test directory to run the installer tests
echo -h Display this help information
@@ -173,6 +210,14 @@ echo. echo If no architecture is specified, all architectures will be built.
echo If --test is not specified, the installer tests are not run.
echo.
+echo For the --pgo option, any Python command line can be used as well as the
+echo following shortcuts:
+echo Shortcut Description
+echo default Test suite with --pgo
+echo default2 2x test suite with --pgo and randomized test order
+echo default10 10x test suite with --pgo and randomized test order
+echo pybench pybench script
+echo.
echo The following substitutions will be applied to the download URL:
echo Variable Description Example
echo {version} version number 3.5.0
diff --git a/Tools/msi/msi.props b/Tools/msi/msi.props index 5b605e9..1e2d3e2 100644 --- a/Tools/msi/msi.props +++ b/Tools/msi/msi.props @@ -110,7 +110,10 @@ </LinkerBindInputPaths> </ItemDefinitionGroup> <ItemGroup> - <LinkerBindInputPaths Include="$(BuildPath);$(PySourcePath)Doc\build\htmlhelp"> + <LinkerBindInputPaths Include="$(PGOBuildPath);$(BuildPath)"> + <BindName></BindName> + </LinkerBindInputPaths> + <LinkerBindInputPaths Include="$(PySourcePath)Doc\build\htmlhelp"> <BindName></BindName> </LinkerBindInputPaths> <LinkerBindInputPaths Include="$(PySourcePath)"> |