| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
| |
Co-authored-by: Tal Einat <taleinat@gmail.com>
Co-authored-by: Łukasz Langa <lukasz@langa.pl>
|
|
|
| |
Enable posix_spawn() on Solaris
|
|
|
| |
Co-authored-by: Terry Jan Reedy <tjreedy@udel.edu>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Removes the `list` call in the Popen `repr`.
Current implementation:
For cmd = `python --version`, with `shell=True`.
```bash
<Popen: returncode: None args: ['p', 'y', 't', 'h', 'o', 'n', ' ', '-', '-',...>
```
For `shell=False` and args=`['python', '--version']`, the output is correct:
```bash
<Popen: returncode: None args: ['python', '--version']>
```
With the new changes the `repr` yields:
For cmd = `python --version`, with `shell=True`:
```bash
<Popen: returncode: None args: 'python --version'>
```
For `shell=False` and args=`['python', '--version']`, the output:
```bash
<Popen: returncode: None args: ['python', '--version']>
```
Automerge-Triggered-By: GH:gpshead
|
|
|
|
|
|
|
|
|
|
|
| |
See [PEP 597](https://www.python.org/dev/peps/pep-0597/).
* Add `-X warn_default_encoding` and `PYTHONWARNDEFAULTENCODING`.
* Add EncodingWarning
* Add io.text_encoding()
* open(), TextIOWrapper() emits EncodingWarning when encoding is omitted and warn_default_encoding is enabled.
* _pyio.TextIOWrapper() uses UTF-8 as fallback default encoding used when failed to import locale module. (used during building Python)
* bz2, configparser, gzip, lzma, pathlib, tempfile modules use io.text_encoding().
* What's new entry
|
|
|
|
|
| |
The shutil and subprocess modules now only import the grp and pwd
modules when they are needed, which is not the case by default in
subprocess.
|
|
|
|
|
| |
Check to make sure stdout and stderr are not empty before selecting an item from them in Windows subprocess._communicate.
Co-authored-by: Gregory P. Smith <greg@krypto.org>
|
| |
|
|
|
|
|
|
|
|
|
|
| |
When the modern text= spelling of the universal_newlines= parameter was added
for Python 3.7, check_output's special case around input=None was overlooked.
So it behaved differently with universal_newlines=True vs text=True. This
reconciles the behavior to be consistent and adds a test to guarantee it.
Also clarifies the existing check_output documentation.
Co-authored-by: Alexey Izbyshev <izbyshev@ispras.ru>
|
|
|
|
|
|
|
| |
subprocess.Popen.send_signal. (GH-20010)
send_signal() now swallows the exception if the process it thought was still alive winds up not to exist anymore (always a plausible race condition despite the checks).
Co-authored-by: Gregory P. Smith <greg@krypto.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
F_SETPIPE_SZ to fcntl. (GH-21921)
* Add F_SETPIPE_SZ and F_GETPIPE_SZ to fcntl module
* Add pipesize parameter for subprocess.Popen class
This will allow the user to control the size of the pipes.
On linux the default is 64K. When a pipe is full it blocks for writing.
When a pipe is empty it blocks for reading. On processes that are
very fast this can lead to a lot of wasted CPU cycles. On a typical
Linux system the max pipe size is 1024K which is much better.
For high performance-oriented libraries such as xopen it is nice to
be able to set the pipe size.
The workaround without this feature is to use my_popen_process.stdout.fileno() in
conjuction with fcntl and 1031 (value of F_SETPIPE_SZ) to acquire this behavior.
|
|
|
| |
This commit removes the old parser, the deprecated parser module, the old parser compatibility flags and environment variables and all associated support code and documentation.
|
|
|
|
|
|
|
|
|
|
|
| |
* Rename PyConfig.use_peg to _use_peg_parser
* Document PyConfig._use_peg_parser and mark it a deprecated
* Mark -X oldparser option and PYTHONOLDPARSER env var as deprecated
in the documentation.
* Add use_old_parser() and skip_if_new_parser() to test.support
* Remove sys.flags.use_peg: use_old_parser() uses
_testinternalcapi.get_configs() instead.
* Enhance test_embed tests
* subprocess._args_from_interpreter_flags() copies -X oldparser
|
|
|
|
|
|
|
|
|
|
|
|
| |
This implements things like `list[int]`,
which returns an object of type `types.GenericAlias`.
This object mostly acts as a proxy for `list`,
but has attributes `__origin__` and `__args__`
that allow recovering the parts (with values `list` and `(int,)`.
There is also an approximate notion of type variables;
e.g. `list[T]` has a `__parameters__` attribute equal to `(T,)`.
Type variables are objects of type `typing.TypeVar`.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Add os.waitstatus_to_exitcode() function to convert a wait status to an
exitcode.
Suggest waitstatus_to_exitcode() usage in the documentation when
appropriate.
Use waitstatus_to_exitcode() in:
* multiprocessing, os, subprocess and _bootsubprocess modules;
* test.support.wait_process();
* setup.py: run_command();
* and many tests.
|
|
|
|
|
|
|
|
|
|
|
| |
Remove:
* COUNT_ALLOCS macro
* sys.getcounts() function
* SHOW_ALLOC_COUNT code in listobject.c
* SHOW_TRACK_COUNT code in tupleobject.c
* PyConfig.show_alloc_count field
* -X showalloccount command line option
* @test.support.requires_type_collecting decorator
|
|
|
|
|
|
|
|
|
| |
(GH-18117)
When communicate() is called in a loop, it crashes when the child process
has already closed any piped standard stream, but still continues to be running
Co-authored-by: Andriy Maletsky <andriy.maletsky@gmail.com>
|
|
|
|
|
|
|
| |
On Unix, subprocess.Popen.send_signal() now polls the process status.
Polling reduces the risk of sending a signal to the wrong process if
the process completed, the Popen.returncode attribute is still None,
and the pid has been reassigned (recycled) to a new different
process.
|
| |
|
| |
|
|
|
|
| |
On POSIX systems, allow the umask to be set in the child process before we exec.
|
|
|
|
|
| |
* subprocess.Popen now longer uses posix_spawn() if uid, gid or gids are set.
* test_subprocess: add "nobody" and "nfsnobody" group names for test_group().
* test_subprocess: test_user() and test_group() are now also tested with close_fds=False.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
* subprocess: Add user, group and extra_groups paremeters to subprocess.Popen
This adds a `user` parameter to the Popen constructor that will call
setreuid() in the child before calling exec(). This allows processes
running as root to safely drop privileges before running the subprocess
without having to use a preexec_fn.
This also adds a `group` parameter that will call setregid() in
the child process before calling exec().
Finally an `extra_groups` parameter was added that will call
setgroups() to set the supplimental groups.
|
|
|
|
|
|
|
| |
Fixes a possible hang when using a timeout on subprocess.run() while
capturing output. If the child process spawned its own children or otherwise
connected its stdout or stderr handles with another process, we could hang
after the timeout was reached and our child was killed when attempting to read
final output from the pipes.
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
As noted by @eryksun in [1] and [2], using _cleanup and _active(in
__del__) is not necessary on Windows, since:
> Unlike Unix, a process in Windows doesn't have to be waited on by
> its parent to avoid a zombie. Keeping the handle open will actually
> create a zombie until the next _cleanup() call, which may be never
> if Popen() isn't called again.
This patch simply defines `subprocess._active` as `None`, for which we already
have the proper logic in place in `subprocess.Popen.__del__`, that prevents it
from trying to append the process to the `_active`. This patch also defines
`subprocess._cleanup` as a noop for Windows.
[1] https://bugs.python.org/issue37380#msg346333
[2] https://bugs.python.org/issue36067#msg336262
Signed-off-by: Ruslan Kuprieiev <ruslan@iterative.ai>
|
| |
|
|
|
|
|
|
| |
Fix an unintended ValueError from :func:`subprocess.run` when checking for
conflicting `input` and `stdin` or `capture_output` and `stdout` or `stderr` args
when they were explicitly provided but with `None` values within a passed in
`**kwargs` dict rather than as passed directly by name.
|
| |
|
|
|
|
| |
Classes that define __str__ the same as __repr__ can
just inherit it from object.
|
|
|
|
|
|
|
| |
Close pipes/fds in subprocess by using ExitStack.
"In case of premature failure on X.Close() or os.close(X) the remaining pipes/fds will remain "open". Perhaps it makes sense to use contextlib.ExitStack."
- Rationale: https://github.com/python/cpython/pull/11575#discussion_r250288394
|
| |
|
|
|
|
|
|
| |
* subprocess.Popen can now also use os.posix_spawn() with pipes,
but only if pipe file descriptors are greater than 2.
* Fix Popen._posix_spawn(): set '_child_created' attribute to True.
* Add Popen._close_pipe_fds() helper function to factorize the code.
|
|
|
| |
This reverts commit 07858894689047c77f9c12ddc061d30681368d19.
|
|
|
|
| |
The subprocess module can now use the os.posix_spawnp() function,
if it is available, to locate the program in the PATH.
|
|
|
|
|
|
|
|
|
|
|
|
| |
The subprocess module can now use the os.posix_spawn() function
in some cases for better performance. Currently, it is only used on macOS
and Linux (using glibc 2.24 or newer) if all these conditions are met:
* executable path contains a directory
* close_fds=False
* preexec_fn, pass_fds, cwd, stdin, stdout, stderr
and start_new_session parameters are not set
Co-authored-by: Joannah Nanjekye <nanjekyejoannah@gmail.com>
|
|
|
|
|
|
|
|
| |
The "-I" command line option (run Python in isolated mode) is now
also copied by the multiprocessing and distutils modules when
spawning child processes. Previously, only -E and -s options (enabled
by -I) were copied.
subprocess._args_from_interpreter_flags() now copies the -I flag.
|
|
|
|
|
|
|
|
|
| |
If buffering=1 is specified for open() in binary mode, it is silently
treated as buffering=-1 (i.e., the default buffer size).
Coupled with the fact that line buffering is always supported in Python 2,
such behavior caused several issues (e.g., bpo-10344, bpo-21332).
Warn that line buffering is not supported if open() is called with
binary mode and buffering=1.
|
|
|
|
|
| |
(GH-9163)
8621bb5d93239316f97281826461b85072ff6db7 sets the filename in directly in the FileNotFoundError, so we may revert the earlier fix 5f780400572508a8179de6a6c13b58b7be417ef5.
|
|
|
|
| |
Check for functionality via imports rather than checking sys.platform
specifically for Windows
|
|
|
|
|
|
|
| |
subprocess.Popen now copies the startupinfo argument to leave it
unchanged: it will modify the copy, so that the same STARTUPINFO
object can be used multiple times.
Add subprocess.STARTUPINFO.copy() method.
|
|
|
|
|
|
| |
* Revert "bpo-31961: subprocess now accepts path-like args (GH-4329)"
This reverts commit dd42cb71f2cb02f3a32f016137b12a146bc0d0e2.
|
|
|
| |
Allow os.PathLike args in subprocess APIs.
|
|
|
|
| |
Add "capture_output=True" option to subprocess.run, this is equivalent to
setting stdout=PIPE, stderr=PIPE but is much more readable.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Do not allow receiving a SIGINT to cause the subprocess module to trigger an
immediate SIGKILL of the child process. SIGINT is normally sent to all child
processes by the OS at the same time already as was the established normal
behavior in 2.7 and 3.2. This behavior change was introduced during the fix to https://bugs.python.org/issue12494 and is generally surprising to command line
tool users who expect other tools launched in child processes to get their own
SIGINT and do their own cleanup.
In Python 3.3-3.6 subprocess.call and subprocess.run would immediately
SIGKILL the child process upon receiving a SIGINT (which raises a
KeyboardInterrupt). We now give the child a small amount of time to
exit gracefully before resorting to a SIGKILL.
This is also the case for subprocess.Popen.__exit__ which would
previously block indefinitely waiting for the child to die. This was
hidden from many users by virtue of subprocess.call and subprocess.run
sending the signal immediately.
Behavior change: subprocess.Popen.__exit__ will not block indefinitely
when the exiting exception is a KeyboardInterrupt. This is done for
user friendliness as people expect their ^C to actually happen. This
could cause occasional orphaned Popen objects when not using `call` or
`run` with a child process that hasn't exited.
Refactoring involved: The Popen.wait method deals with the
KeyboardInterrupt second chance, existing platform specific internals
have been renamed to _wait().
Also fixes comment typos.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Windows (#1218)
Even though Python marks any handles it opens as non-inheritable there
is still a race when using `subprocess.Popen` since creating a process
with redirected stdio requires temporarily creating inheritable handles.
By implementing support for `subprocess.Popen(close_fds=True)` we fix
this race.
In order to implement this we use PROC_THREAD_ATTRIBUTE_HANDLE_LIST
which is available since Windows Vista. Which allows to pass an explicit
list of handles to inherit when creating a process.
This commit also adds `STARTUPINFO.lpAttributeList["handle_list"]`
which can be used to control PROC_THREAD_ATTRIBUTE_HANDLE_LIST
directly.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
* Add -X utf8 command line option, PYTHONUTF8 environment variable
and a new sys.flags.utf8_mode flag.
* If the LC_CTYPE locale is "C" at startup: enable automatically the
UTF-8 mode.
* Add _winapi.GetACP(). encodings._alias_mbcs() now calls
_winapi.GetACP() to get the ANSI code page
* locale.getpreferredencoding() now returns 'UTF-8' in the UTF-8
mode. As a side effect, open() now uses the UTF-8 encoding by
default in this mode.
* Py_DecodeLocale() and Py_EncodeLocale() now use the UTF-8 encoding
in the UTF-8 Mode.
* Update subprocess._args_from_interpreter_flags() to handle -X utf8
* Skip some tests relying on the current locale if the UTF-8 mode is
enabled.
* Add test_utf8mode.py.
* _Py_DecodeUTF8_surrogateescape() gets a new optional parameter to
return also the length (number of wide characters).
* pymain_get_global_config() and pymain_set_global_config() now
always copy flag values, rather than only copying if the new value
is greater than the old value.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Rather than supporting dev mode directly in the warnings module, this
instead adjusts the initialisation code to add an extra 'default'
entry to sys.warnoptions when dev mode is enabled.
This ensures that dev mode behaves *exactly* as if `-Wdefault` had
been passed on the command line, including in the way it interacts
with `sys.warnoptions`, and with other command line flags like `-bb`.
Fix also bpo-20361: have -b & -bb options take precedence over any
other warnings options.
Patch written by Nick Coghlan, with minor modifications of Victor Stinner.
|
|
|
|
|
|
|
|
|
|
| |
The developer mode (-X dev) now creates all default warnings filters
to order filters in the correct order to always show ResourceWarning
and make BytesWarning depend on the -b option.
Write a functional test to make sure that ResourceWarning is logged
twice at the same location in the developer mode.
Add a new 'dev_mode' field to _PyCoreConfig.
|
|
|
|
|
|
|
|
| |
Modify subprocess._args_from_interpreter_flags() to handle -X dev
option.
Add also unit tests for test.support.args_from_interpreter_flags()
and test.support.optim_args_from_interpreter_flags().
|