summaryrefslogtreecommitdiffstats
path: root/Doc/library/signal.rst
blob: 7d8d7d671006809918ecad4bcc26b8a41d2b12bd (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
:mod:`signal` --- Set handlers for asynchronous events
======================================================

.. module:: signal
   :synopsis: Set handlers for asynchronous events.


This module provides mechanisms to use signal handlers in Python. Some general
rules for working with signals and their handlers:

* A handler for a particular signal, once set, remains installed until it is
  explicitly reset (Python emulates the BSD style interface regardless of the
  underlying implementation), with the exception of the handler for
  :const:`SIGCHLD`, which follows the underlying implementation.

* There is no way to "block" signals temporarily from critical sections (since
  this is not supported by all Unix flavors).

* Although Python signal handlers are called asynchronously as far as the Python
  user is concerned, they can only occur between the "atomic" instructions of the
  Python interpreter.  This means that signals arriving during long calculations
  implemented purely in C (such as regular expression matches on large bodies of
  text) may be delayed for an arbitrary amount of time.

* When a signal arrives during an I/O operation, it is possible that the I/O
  operation raises an exception after the signal handler returns. This is
  dependent on the underlying Unix system's semantics regarding interrupted system
  calls.

* Because the C signal handler always returns, it makes little sense to catch
  synchronous errors like :const:`SIGFPE` or :const:`SIGSEGV`.

* Python installs a small number of signal handlers by default: :const:`SIGPIPE`
  is ignored (so write errors on pipes and sockets can be reported as ordinary
  Python exceptions) and :const:`SIGINT` is translated into a
  :exc:`KeyboardInterrupt` exception.  All of these can be overridden.

* Some care must be taken if both signals and threads are used in the same
  program.  The fundamental thing to remember in using signals and threads
  simultaneously is: always perform :func:`signal` operations in the main thread
  of execution.  Any thread can perform an :func:`alarm`, :func:`getsignal`,
  :func:`pause`, :func:`setitimer` or :func:`getitimer`; only the main thread
  can set a new signal handler, and the main thread will be the only one to
  receive signals (this is enforced by the Python :mod:`signal` module, even
  if the underlying thread implementation supports sending signals to
  individual threads).  This means that signals can't be used as a means of
  inter-thread communication.  Use locks instead.

The variables defined in the :mod:`signal` module are:


.. data:: SIG_DFL

   This is one of two standard signal handling options; it will simply perform
   the default function for the signal.  For example, on most systems the
   default action for :const:`SIGQUIT` is to dump core and exit, while the
   default action for :const:`SIGCHLD` is to simply ignore it.


.. data:: SIG_IGN

   This is another standard signal handler, which will simply ignore the given
   signal.


.. data:: SIG*

   All the signal numbers are defined symbolically.  For example, the hangup signal
   is defined as :const:`signal.SIGHUP`; the variable names are identical to the
   names used in C programs, as found in ``<signal.h>``. The Unix man page for
   ':cfunc:`signal`' lists the existing signals (on some systems this is
   :manpage:`signal(2)`, on others the list is in :manpage:`signal(7)`). Note that
   not all systems define the same set of signal names; only those names defined by
   the system are defined by this module.


.. data:: CTRL_C_EVENT

   The signal corresponding to the CTRL+C keystroke event. This signal can
   only be used with :func:`os.kill`.

   Availability: Windows.

   .. versionadded:: 3.2


.. data:: CTRL_BREAK_EVENT

   The signal corresponding to the CTRL+BREAK keystroke event. This signal can
   only be used with :func:`os.kill`.

   Availability: Windows.

   .. versionadded:: 3.2


.. data:: NSIG

   One more than the number of the highest signal number.


.. data:: ITIMER_REAL

   Decrements interval timer in real time, and delivers :const:`SIGALRM` upon
   expiration.


.. data:: ITIMER_VIRTUAL

   Decrements interval timer only when the process is executing, and delivers
   SIGVTALRM upon expiration.


.. data:: ITIMER_PROF

   Decrements interval timer both when the process executes and when the
   system is executing on behalf of the process. Coupled with ITIMER_VIRTUAL,
   this timer is usually used to profile the time spent by the application
   in user and kernel space. SIGPROF is delivered upon expiration.


The :mod:`signal` module defines one exception:

.. exception:: ItimerError

   Raised to signal an error from the underlying :func:`setitimer` or
   :func:`getitimer` implementation. Expect this error if an invalid
   interval timer or a negative time is passed to :func:`setitimer`.
   This error is a subtype of :exc:`IOError`.


The :mod:`signal` module defines the following functions:


.. function:: alarm(time)

   If *time* is non-zero, this function requests that a :const:`SIGALRM` signal be
   sent to the process in *time* seconds. Any previously scheduled alarm is
   canceled (only one alarm can be scheduled at any time).  The returned value is
   then the number of seconds before any previously set alarm was to have been
   delivered. If *time* is zero, no alarm is scheduled, and any scheduled alarm is
   canceled.  If the return value is zero, no alarm is currently scheduled.  (See
   the Unix man page :manpage:`alarm(2)`.) Availability: Unix.


.. function:: getsignal(signalnum)

   Return the current signal handler for the signal *signalnum*. The returned value
   may be a callable Python object, or one of the special values
   :const:`signal.SIG_IGN`, :const:`signal.SIG_DFL` or :const:`None`.  Here,
   :const:`signal.SIG_IGN` means that the signal was previously ignored,
   :const:`signal.SIG_DFL` means that the default way of handling the signal was
   previously in use, and ``None`` means that the previous signal handler was not
   installed from Python.


.. function:: pause()

   Cause the process to sleep until a signal is received; the appropriate handler
   will then be called.  Returns nothing.  Not on Windows. (See the Unix man page
   :manpage:`signal(2)`.)


.. function:: setitimer(which, seconds[, interval])

   Sets given interval timer (one of :const:`signal.ITIMER_REAL`,
   :const:`signal.ITIMER_VIRTUAL` or :const:`signal.ITIMER_PROF`) specified
   by *which* to fire after *seconds* (float is accepted, different from
   :func:`alarm`) and after that every *interval* seconds. The interval
   timer specified by *which* can be cleared by setting seconds to zero.

   When an interval timer fires, a signal is sent to the process.
   The signal sent is dependent on the timer being used;
   :const:`signal.ITIMER_REAL` will deliver :const:`SIGALRM`,
   :const:`signal.ITIMER_VIRTUAL` sends :const:`SIGVTALRM`,
   and :const:`signal.ITIMER_PROF` will deliver :const:`SIGPROF`.

   The old values are returned as a tuple: (delay, interval).

   Attempting to pass an invalid interval timer will cause an
   :exc:`ItimerError`.  Availability: Unix.


.. function:: getitimer(which)

   Returns current value of a given interval timer specified by *which*.
   Availability: Unix.


.. function:: set_wakeup_fd(fd)

   Set the wakeup fd to *fd*.  When a signal is received, a ``'\0'`` byte is
   written to the fd.  This can be used by a library to wakeup a poll or select
   call, allowing the signal to be fully processed.

   The old wakeup fd is returned.  *fd* must be non-blocking.  It is up to the
   library to remove any bytes before calling poll or select again.

   When threads are enabled, this function can only be called from the main thread;
   attempting to call it from other threads will cause a :exc:`ValueError`
   exception to be raised.


.. function:: siginterrupt(signalnum, flag)

   Change system call restart behaviour: if *flag* is :const:`False`, system
   calls will be restarted when interrupted by signal *signalnum*, otherwise
   system calls will be interrupted.  Returns nothing.  Availability: Unix (see
   the man page :manpage:`siginterrupt(3)` for further information).

   Note that installing a signal handler with :func:`signal` will reset the
   restart behaviour to interruptible by implicitly calling
   :cfunc:`siginterrupt` with a true *flag* value for the given signal.


.. function:: signal(signalnum, handler)

   Set the handler for signal *signalnum* to the function *handler*.  *handler* can
   be a callable Python object taking two arguments (see below), or one of the
   special values :const:`signal.SIG_IGN` or :const:`signal.SIG_DFL`.  The previous
   signal handler will be returned (see the description of :func:`getsignal`
   above).  (See the Unix man page :manpage:`signal(2)`.)

   When threads are enabled, this function can only be called from the main thread;
   attempting to call it from other threads will cause a :exc:`ValueError`
   exception to be raised.

   The *handler* is called with two arguments: the signal number and the current
   stack frame (``None`` or a frame object; for a description of frame objects,
   see the :ref:`description in the type hierarchy <frame-objects>` or see the
   attribute descriptions in the :mod:`inspect` module).

   On Windows, :func:`signal` can only be called with :const:`SIGABRT`,
   :const:`SIGFPE`, :const:`SIGILL`, :const:`SIGINT`, :const:`SIGSEGV`, or
   :const:`SIGTERM`. A :exc:`ValueError` will be raised in any other case.


.. _signal-example:

Example
-------

Here is a minimal example program. It uses the :func:`alarm` function to limit
the time spent waiting to open a file; this is useful if the file is for a
serial device that may not be turned on, which would normally cause the
:func:`os.open` to hang indefinitely.  The solution is to set a 5-second alarm
before opening the file; if the operation takes too long, the alarm signal will
be sent, and the handler raises an exception. ::

   import signal, os

   def handler(signum, frame):
       print('Signal handler called with signal', signum)
       raise IOError("Couldn't open device!")

   # Set the signal handler and a 5-second alarm
   signal.signal(signal.SIGALRM, handler)
   signal.alarm(5)

   # This open() may hang indefinitely
   fd = os.open('/dev/ttyS0', os.O_RDWR)

   signal.alarm(0)          # Disable the alarm