diff options
author | dkf <donal.k.fellows@manchester.ac.uk> | 2003-04-18 00:28:13 (GMT) |
---|---|---|
committer | dkf <donal.k.fellows@manchester.ac.uk> | 2003-04-18 00:28:13 (GMT) |
commit | dbc6111db18e96f64cb16c8e198eeec40a15fcc0 (patch) | |
tree | 4e92266dd5691d7298f68443614e1b311f7283ac /doc/fconfigure.n | |
parent | 221d64cae9a7781a4b3dd2a2e2e273fd6196c09e (diff) | |
download | tcl-dbc6111db18e96f64cb16c8e198eeec40a15fcc0.zip tcl-dbc6111db18e96f64cb16c8e198eeec40a15fcc0.tar.gz tcl-dbc6111db18e96f64cb16c8e198eeec40a15fcc0.tar.bz2 |
Moved serial line options to their creator, open.n, from the generic page
fconfigure.n which was never an obvious spot for them. [Bug 679010]
Diffstat (limited to 'doc/fconfigure.n')
-rw-r--r-- | doc/fconfigure.n | 198 |
1 files changed, 2 insertions, 196 deletions
diff --git a/doc/fconfigure.n b/doc/fconfigure.n index da52671..f8db0fc 100644 --- a/doc/fconfigure.n +++ b/doc/fconfigure.n @@ -4,7 +4,7 @@ '\" See the file "license.terms" for information on usage and redistribution '\" of this file, and for a DISCLAIMER OF ALL WARRANTIES. '\" -'\" RCS: @(#) $Id: fconfigure.n,v 1.7 2002/07/01 18:24:39 jenglish Exp $ +'\" RCS: @(#) $Id: fconfigure.n,v 1.8 2003/04/18 00:28:14 dkf Exp $ '\" .so man.macros .TH fconfigure n 8.3 Tcl "Tcl Built-In Commands" @@ -203,202 +203,8 @@ If, for example, a Tcl application is started by the \fBinet\fR super-server common on Unix system its Tcl standard channels will be sockets and thus support the socket options. -.VS 8.4 -.SH "SERIAL PORT CONFIGURATION OPTIONS" -.PP -If \fIchannelId\fR refers to a serial port, then the following -additional configuration options are available on Windows and -Unix systems with a POSIX serial interface: - -.TP -\fB\-mode\fR \fIbaud\fB,\fIparity\fB,\fIdata\fB,\fIstop\fR -. -This option is a set of 4 comma-separated values: the baud rate, parity, -number of data bits, and number of stop bits for this serial port. The -\fIbaud\fR rate is a simple integer that specifies the connection speed. -\fIParity\fR is one of the following letters: \fBn\fR, \fBo\fR, \fBe\fR, -\fBm\fR, \fBs\fR; respectively signifying the parity options of ``none'', -``odd'', ``even'', ``mark'', or ``space''. \fIData\fR is the number of -data bits and should be an integer from 5 to 8, while \fIstop\fR is the -number of stop bits and should be the integer 1 or 2. - -.TP -\fB\-handshake\fR \fItype\fR -. -(Windows and Unix). This option is used to setup automatic handshake -control. Note that not all handshake types maybe supported by your operating -system. The \fItype\fR parameter is case-independent. - -If \fItype\fR is \fBnone\fR then any handshake is switched off. -\fBrtscts\fR activates hardware handshake. Hardware handshake signals -are described below. -For software handshake \fBxonxoff\fR the handshake characters can be redefined -with \fB-xchar\fR. -An additional hardware handshake \fBdtrdsr\fR is available only under Windows. -There is no default handshake configuration, the initial value depends -on your operating system settings. -The \fB-handshake\fR option cannot be queried. - -.TP -\fB\-queue\fR -. -(Windows and Unix). The \fB-queue\fR option can only be queried. -It returns a list of two integers representing the current number -of bytes in the input and output queue respectively. - -.TP -\fB\-timeout\fR \fImsec\fR -. -(Windows and Unix). This option is used to set the timeout for blocking -read operations. It specifies the maximum interval between the -reception of two bytes in milliseconds. -For Unix systems the granularity is 100 milliseconds. -The \fB-timeout\fR option does not affect write operations or -nonblocking reads. -This option cannot be queried. - -.TP -\fB\-ttycontrol\fR \fI{signal boolean signal boolean ...}\fR -. -(Windows and Unix). This option is used to setup the handshake -output lines (see below) permanently or to send a BREAK over the serial line. -The \fIsignal\fR names are case-independent. -\fB{RTS 1 DTR 0}\fR sets the RTS output to high and the DTR output to low. -The BREAK condition (see below) is enabled and disabled with \fB{BREAK 1}\fR and -\fB{BREAK 0}\fR respectively. -It's not a good idea to change the \fBRTS\fR (or \fBDTR\fR) signal -with active hardware handshake \fBrtscts\fR (or \fBdtrdsr\fR). -The result is unpredictable. -The \fB-ttycontrol\fR option cannot be queried. - -.TP -\fB\-ttystatus\fR -. -(Windows and Unix). The \fB-ttystatus\fR option can only be -queried. It returns the current modem status and handshake input signals -(see below). -The result is a list of signal,value pairs with a fixed order, -e.g. \fB{CTS 1 DSR 0 RING 1 DCD 0}\fR. -The \fIsignal\fR names are returned upper case. - -.TP -\fB\-xchar\fR \fI{xonChar xoffChar}\fR -. -(Windows and Unix). This option is used to query or change the software -handshake characters. Normally the operating system default should be -DC1 (0x11) and DC3 (0x13) representing the ASCII standard -XON and XOFF characters. - -.TP -\fB\-pollinterval\fR \fImsec\fR -. -(Windows only). This option is used to set the maximum time between -polling for fileevents. -This affects the time interval between checking for events throughout the Tcl -interpreter (the smallest value always wins). Use this option only if -you want to poll the serial port more or less often than 10 msec -(the default). - -.TP -\fB\-sysbuffer\fR \fIinSize\fR -.TP -\fB\-sysbuffer\fR \fI{inSize outSize}\fR -. -(Windows only). This option is used to change the size of Windows -system buffers for a serial channel. Especially at higher communication -rates the default input buffer size of 4096 bytes can overrun -for latent systems. The first form specifies the input buffer size, -in the second form both input and output buffers are defined. - -.TP -\fB\-lasterror\fR -. -(Windows only). This option is query only. -In case of a serial communication error, \fBread\fR or \fBputs\fR -returns a general Tcl file I/O error. -\fBfconfigure -lasterror\fR can be called to get a list of error details. -See below for an explanation of the various error codes. - -.SH "SERIAL PORT SIGNALS" -.PP -RS-232 is the most commonly used standard electrical interface for serial -communications. A negative voltage (-3V..-12V) define a mark (on=1) bit and -a positive voltage (+3..+12V) define a space (off=0) bit (RS-232C). The -following signals are specified for incoming and outgoing data, status -lines and handshaking. Here we are using the terms \fIworkstation\fR for -your computer and \fImodem\fR for the external device, because some signal -names (DCD, RI) come from modems. Of course your external device may use -these signal lines for other purposes. -.RS -.IP \fBTXD(output)\fR -\fBTransmitted Data:\fR Outgoing serial data. -.IP \fBRXD(input)\fR -\fBReceived Data:\fRIncoming serial data. -.IP \fBRTS(output)\fR -\fBRequest To Send:\fR This hardware handshake line informs the modem that -your workstation is ready to receive data. Your workstation may -automatically reset this signal to indicate that the input buffer is full. -.IP \fBCTS(input)\fR -\fBClear To Send:\fR The complement to RTS. Indicates that the modem is -ready to receive data. -.IP \fBDTR(output)\fR -\fBData Terminal Ready:\fR This signal tells the modem that the workstation -is ready to establish a link. DTR is often enabled automatically whenever a -serial port is opened. -.IP \fBDSR(input)\fR -\fBData Set Ready:\fR The complement to DTR. Tells the workstation that the -modem is ready to establish a link. -.IP \fBDCD(input)\fR -\fBData Carrier Detect:\fR This line becomes active when a modem detects -a "Carrier" signal. -.IP \fBRI(input)\fR -\fBRing Indicator:\fR Goes active when the modem detects an incoming call. -.IP \fBBREAK\fR -A BREAK condition is not a hardware signal line, but a logical zero on the -TXD or RXD lines for a long period of time, usually 250 to 500 -milliseconds. Normally a receive or transmit data signal stays at the mark -(on=1) voltage until the next character is transferred. A BREAK is sometimes -used to reset the communications line or change the operating mode of -communications hardware. -.RE - -.SH "ERROR CODES (Windows only)" -.PP -A lot of different errors may occur during serial read operations or during -event polling in background. The external device may have been switched -off, the data lines may be noisy, system buffers may overrun or your mode -settings may be wrong. That's why a reliable software should always -\fBcatch\fR serial read operations. In cases of an error Tcl returns a -general file I/O error. Then \fBfconfigure -lasterror\fR may help to -locate the problem. The following error codes may be returned. -.RS -.IP \fBRXOVER:\fR -Windows input buffer overrun. The data comes faster than your scripts reads -it or your system is overloaded. Use \fBfconfigure -sysbuffer\fR to avoid a -temporary bottleneck and/or make your script faster. -.IP \fBTXFULL\fR -Windows output buffer overrun. Complement to RXOVER. This error should -practically not happen, because Tcl cares about the output buffer status. -.IP \fBOVERRUN\fR -UART buffer overrun (hardware) with data lost. -The data comes faster than the system driver receives it. -Check your advanced serial port settings to enable the FIFO (16550) buffer -and/or setup a lower(1) interrupt threshold value. -.IP \fBRXPARITY\fR -A parity error has been detected by your UART. -Wrong parity settings with \fBfconfigure -mode\fR or a noisy data line (RXD) -may cause this error. -.IP \fBFRAME\fR -A stop-bit error has been detected by your UART. -Wrong mode settings with \fBfconfigure -mode\fR or a noisy data line (RXD) -may cause this error. -.IP \fBBREAK\fR -A BREAK condition has been detected by your UART (see above). -.RE -.VE - .SH "SEE ALSO" -close(n), flush(n), gets(n), puts(n), read(n), socket(n), +close(n), flush(n), gets(n), open(n), puts(n), read(n), socket(n), Tcl_StandardChannels(3) .SH KEYWORDS |