1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
|
/***********************************************************
Copyright 1994 by Lance Ellinghouse,
Cathedral City, California Republic, United States of America.
All Rights Reserved
Permission to use, copy, modify, and distribute this software and its
documentation for any purpose and without fee is hereby granted,
provided that the above copyright notice appear in all copies and that
both that copyright notice and this permission notice appear in
supporting documentation, and that the name of Lance Ellinghouse
not be used in advertising or publicity pertaining to distribution
of the software without specific, written prior permission.
LANCE ELLINGHOUSE DISCLAIMS ALL WARRANTIES WITH REGARD TO
THIS SOFTWARE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS, IN NO EVENT SHALL LANCE ELLINGHOUSE BE LIABLE FOR ANY SPECIAL,
INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING
FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT,
NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION
WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.
******************************************************************/
/******************************************************************
Revision history:
1998/04/28 (Sean Reifschneider)
- When facility not specified to syslog() method, use default from openlog()
(This is how it was claimed to work in the documentation)
- Potential resource leak of o_ident, now cleaned up in closelog()
- Minor comment accuracy fix.
95/06/29 (Steve Clift)
- Changed arg parsing to use PyArg_ParseTuple.
- Added PyErr_Clear() call(s) where needed.
- Fix core dumps if user message contains format specifiers.
- Change openlog arg defaults to match normal syslog behavior.
- Plug memory leak in openlog().
- Fix setlogmask() to return previous mask value.
******************************************************************/
/* syslog module */
#include "Python.h"
#include <syslog.h>
/* only one instance, only one syslog, so globals should be ok */
static PyObject *S_ident_o = NULL; /* identifier, held by openlog() */
static PyObject *
syslog_openlog(PyObject * self, PyObject * args)
{
long logopt = 0;
long facility = LOG_USER;
PyObject *new_S_ident_o;
if (!PyArg_ParseTuple(args,
"S|ll;ident string [, logoption [, facility]]",
&new_S_ident_o, &logopt, &facility))
return NULL;
/* This is needed because openlog() does NOT make a copy
* and syslog() later uses it.. cannot trash it.
*/
Py_XDECREF(S_ident_o);
S_ident_o = new_S_ident_o;
Py_INCREF(S_ident_o);
openlog(PyString_AsString(S_ident_o), logopt, facility);
Py_INCREF(Py_None);
return Py_None;
}
static PyObject *
syslog_syslog(PyObject * self, PyObject * args)
{
char *message;
int priority = LOG_INFO;
if (!PyArg_ParseTuple(args, "is;[priority,] message string",
&priority, &message)) {
PyErr_Clear();
if (!PyArg_ParseTuple(args, "s;[priority,] message string",
&message))
return NULL;
}
syslog(priority, "%s", message);
Py_INCREF(Py_None);
return Py_None;
}
static PyObject *
syslog_closelog(PyObject *self, PyObject *args)
{
if (!PyArg_ParseTuple(args, ":closelog"))
return NULL;
closelog();
Py_XDECREF(S_ident_o);
S_ident_o = NULL;
Py_INCREF(Py_None);
return Py_None;
}
static PyObject *
syslog_setlogmask(PyObject *self, PyObject *args)
{
long maskpri, omaskpri;
if (!PyArg_ParseTuple(args, "l;mask for priority", &maskpri))
return NULL;
omaskpri = setlogmask(maskpri);
return PyInt_FromLong(omaskpri);
}
static PyObject *
syslog_log_mask(PyObject *self, PyObject *args)
{
long mask;
long pri;
if (!PyArg_ParseTuple(args, "l:LOG_MASK", &pri))
return NULL;
mask = LOG_MASK(pri);
return PyInt_FromLong(mask);
}
static PyObject *
syslog_log_upto(PyObject *self, PyObject *args)
{
long mask;
long pri;
if (!PyArg_ParseTuple(args, "l:LOG_UPTO", &pri))
return NULL;
mask = LOG_UPTO(pri);
return PyInt_FromLong(mask);
}
/* List of functions defined in the module */
static PyMethodDef syslog_methods[] = {
{"openlog", syslog_openlog, METH_VARARGS},
{"closelog", syslog_closelog, METH_VARARGS},
{"syslog", syslog_syslog, METH_VARARGS},
{"setlogmask", syslog_setlogmask, METH_VARARGS},
{"LOG_MASK", syslog_log_mask, METH_VARARGS},
{"LOG_UPTO", syslog_log_upto, METH_VARARGS},
{NULL, NULL, 0}
};
/* Initialization function for the module */
PyMODINIT_FUNC
initsyslog(void)
{
PyObject *m;
/* Create the module and add the functions */
m = Py_InitModule("syslog", syslog_methods);
if (m == NULL)
return;
/* Add some symbolic constants to the module */
/* Priorities */
PyModule_AddIntConstant(m, "LOG_EMERG", LOG_EMERG);
PyModule_AddIntConstant(m, "LOG_ALERT", LOG_ALERT);
PyModule_AddIntConstant(m, "LOG_CRIT", LOG_CRIT);
PyModule_AddIntConstant(m, "LOG_ERR", LOG_ERR);
PyModule_AddIntConstant(m, "LOG_WARNING", LOG_WARNING);
PyModule_AddIntConstant(m, "LOG_NOTICE", LOG_NOTICE);
PyModule_AddIntConstant(m, "LOG_INFO", LOG_INFO);
PyModule_AddIntConstant(m, "LOG_DEBUG", LOG_DEBUG);
/* openlog() option flags */
PyModule_AddIntConstant(m, "LOG_PID", LOG_PID);
PyModule_AddIntConstant(m, "LOG_CONS", LOG_CONS);
PyModule_AddIntConstant(m, "LOG_NDELAY", LOG_NDELAY);
#ifdef LOG_NOWAIT
PyModule_AddIntConstant(m, "LOG_NOWAIT", LOG_NOWAIT);
#endif
#ifdef LOG_PERROR
PyModule_AddIntConstant(m, "LOG_PERROR", LOG_PERROR);
#endif
/* Facilities */
PyModule_AddIntConstant(m, "LOG_KERN", LOG_KERN);
PyModule_AddIntConstant(m, "LOG_USER", LOG_USER);
PyModule_AddIntConstant(m, "LOG_MAIL", LOG_MAIL);
PyModule_AddIntConstant(m, "LOG_DAEMON", LOG_DAEMON);
PyModule_AddIntConstant(m, "LOG_AUTH", LOG_AUTH);
PyModule_AddIntConstant(m, "LOG_LPR", LOG_LPR);
PyModule_AddIntConstant(m, "LOG_LOCAL0", LOG_LOCAL0);
PyModule_AddIntConstant(m, "LOG_LOCAL1", LOG_LOCAL1);
PyModule_AddIntConstant(m, "LOG_LOCAL2", LOG_LOCAL2);
PyModule_AddIntConstant(m, "LOG_LOCAL3", LOG_LOCAL3);
PyModule_AddIntConstant(m, "LOG_LOCAL4", LOG_LOCAL4);
PyModule_AddIntConstant(m, "LOG_LOCAL5", LOG_LOCAL5);
PyModule_AddIntConstant(m, "LOG_LOCAL6", LOG_LOCAL6);
PyModule_AddIntConstant(m, "LOG_LOCAL7", LOG_LOCAL7);
#ifndef LOG_SYSLOG
#define LOG_SYSLOG LOG_DAEMON
#endif
#ifndef LOG_NEWS
#define LOG_NEWS LOG_MAIL
#endif
#ifndef LOG_UUCP
#define LOG_UUCP LOG_MAIL
#endif
#ifndef LOG_CRON
#define LOG_CRON LOG_DAEMON
#endif
PyModule_AddIntConstant(m, "LOG_SYSLOG", LOG_SYSLOG);
PyModule_AddIntConstant(m, "LOG_CRON", LOG_CRON);
PyModule_AddIntConstant(m, "LOG_UUCP", LOG_UUCP);
PyModule_AddIntConstant(m, "LOG_NEWS", LOG_NEWS);
}
|