summaryrefslogtreecommitdiffstats
path: root/doc/LinkVar.3
blob: ffedb9d664a710ecd7b97a3176d1b7feec7542fe (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
'\"
'\" Copyright (c) 1993 The Regents of the University of California.
'\" Copyright (c) 1994-1996 Sun Microsystems, Inc.
'\"
'\" See the file "license.terms" for information on usage and redistribution
'\" of this file, and for a DISCLAIMER OF ALL WARRANTIES.
'\"
.TH Tcl_LinkVar 3 7.5 Tcl "Tcl Library Procedures"
.so man.macros
.BS
.SH NAME
Tcl_LinkArray, Tcl_LinkVar, Tcl_UnlinkVar, Tcl_UpdateLinkedVar \- link Tcl variable to C variable
.SH SYNOPSIS
.nf
\fB#include <tcl.h>\fR
.sp
int
\fBTcl_LinkVar\fR(\fIinterp, varName, addr, type\fR)
.sp
.VS "TIP 312"
int
\fBTcl_LinkArray\fR(\fIinterp, varName, addr, type, size\fR)
.VE "TIP 312"
.sp
\fBTcl_UnlinkVar\fR(\fIinterp, varName\fR)
.sp
\fBTcl_UpdateLinkedVar\fR(\fIinterp, varName\fR)
.fi
.SH ARGUMENTS
.AS Tcl_Interp varName in
.AP Tcl_Interp *interp in
Interpreter that contains \fIvarName\fR.
Also used by \fBTcl_LinkVar\fR to return error messages.
.AP "const char" *varName in
Name of global variable.
.AP void *addr in
Address of C variable that is to be linked to \fIvarName\fR.
.sp
.VS "TIP 312"
In \fBTcl_LinkArray\fR, may be NULL to tell Tcl to create the storage
for the array in the variable.
.VE "TIP 312"
.AP int type in
Type of C variable for \fBTcl_LinkVar\fR or type of array element for
\fBTcl_LinkArray\fR.  Must be one of \fBTCL_LINK_INT\fR,
\fBTCL_LINK_UINT\fR, \fBTCL_LINK_CHAR\fR, \fBTCL_LINK_UCHAR\fR,
\fBTCL_LINK_SHORT\fR, \fBTCL_LINK_USHORT\fR, \fBTCL_LINK_LONG\fR,
\fBTCL_LINK_ULONG\fR, \fBTCL_LINK_WIDE_INT\fR,
\fBTCL_LINK_WIDE_UINT\fR, \fBTCL_LINK_FLOAT\fR, \fBTCL_LINK_DOUBLE\fR,
\fBTCL_LINK_BOOLEAN\fR, or one of the extra ones listed below.
.sp
In \fBTcl_LinkVar\fR, the additional linked type \fBTCL_LINK_STRING\fR may be
used.
.sp
.VS "TIP 312"
In \fBTcl_LinkArray\fR, the additional linked types \fBTCL_LINK_CHARS\fR and
\fBTCL_LINK_BINARY\fR may be used.
.VE "TIP 312"
.sp
All the above for both functions may be
optionally OR'ed with \fBTCL_LINK_READ_ONLY\fR to make the Tcl
variable read-only.
.AP Tcl_Size size in
.VS "TIP 312"
The number of elements in the C array. Must be greater than zero.
.VE "TIP 312"
.BE
.SH DESCRIPTION
.PP
\fBTcl_LinkVar\fR uses variable traces to keep the Tcl variable
named by \fIvarName\fR in sync with the C variable at the address
given by \fIaddr\fR.
Whenever the Tcl variable is read the value of the C variable will
be returned, and whenever the Tcl variable is written the C
variable will be updated to have the same value.
\fBTcl_LinkVar\fR normally returns \fBTCL_OK\fR;  if an error occurs
while setting up the link (e.g. because \fIvarName\fR is the
name of array) then \fBTCL_ERROR\fR is returned and the interpreter's result
contains an error message.
.PP
.VS "TIP 312"
\fBTcl_LinkArray\fR is similar, but for arrays of fixed size (given by
the \fIsize\fR argument). When asked to allocate the backing C array
storage (via the \fIaddr\fR argument being NULL), it writes the
address that it allocated to the Tcl interpreter result.
.VE "TIP 312"
.PP
The \fItype\fR argument specifies the type of the C variable,
or the type of the elements of the C array,
and must have one of the following values, optionally OR'ed with
\fBTCL_LINK_READ_ONLY\fR:
.TP
\fBTCL_LINK_INT\fR
.
The C variable, or each element of the C array, is of type \fBint\fR.
Any value written into the Tcl variable must have a proper integer
form acceptable to \fBTcl_GetIntFromObj\fR;  attempts to write
non-integer values into \fIvarName\fR will be rejected with
Tcl errors. Incomplete integer representations (like the empty
string, '+', '-' or the hex/octal/decimal/binary prefix) are accepted
as if they are valid too.
.TP
\fBTCL_LINK_UINT\fR
.
The C variable, or each element of the C array, is of type \fBunsigned int\fR.
Any value written into the Tcl variable must have a proper unsigned
integer form acceptable to \fBTcl_GetWideIntFromObj\fR and in the
platform's defined range for the \fBunsigned int\fR type; attempts to
write non-integer values (or values outside the range) into
\fIvarName\fR will be rejected with Tcl errors. Incomplete integer
representations (like the empty string, '+', '-' or the hex/octal/decimal/binary
prefix) are accepted as if they are valid too.
.TP
\fBTCL_LINK_CHAR\fR
.
The C variable, or each element of the C array, is of type \fBchar\fR.
Any value written into the Tcl variable must have a proper integer
form acceptable to \fBTcl_GetIntFromObj\fR and be in the range of the
\fBchar\fR datatype; attempts to write non-integer or out-of-range
values into \fIvarName\fR will be rejected with Tcl errors. Incomplete
integer representations (like the empty string, '+', '-' or the
hex/octal/decimal/binary prefix) are accepted as if they are valid too.
.RS
.PP
.VS "TIP 312"
If using an array of these, consider using \fBTCL_LINK_CHARS\fR instead.
.VE "TIP 312"
.RE
.TP
\fBTCL_LINK_CHARS\fR
.VS "TIP 312"
The C array is of type \fBchar *\fR and is mapped into Tcl as a string.
Any value written into the Tcl variable must have the same length as
the underlying storage. Only supported with \fBTcl_LinkArray\fR.
.VE "TIP 312"
.TP
\fBTCL_LINK_UCHAR\fR
.
The C variable, or each element of the C array, is of type \fBunsigned char\fR.
Any value written into the Tcl variable must have a proper unsigned
integer form acceptable to \fBTcl_GetIntFromObj\fR and in the
platform's defined range for the \fBunsigned char\fR type; attempts to
write non-integer values (or values outside the range) into
\fIvarName\fR will be rejected with Tcl errors. Incomplete integer
representations (like the empty string, '+', '-' or the hex/octal/decimal/binary
prefix) are accepted as if they are valid too.
.RS
.PP
.VS "TIP 312"
If using an array of these, consider using \fBTCL_LINK_BINARY\fR instead.
.VE "TIP 312"
.RE
.TP
\fBTCL_LINK_BINARY\fR
.VS "TIP 312"
The C array is of type \fBunsigned char *\fR and is mapped into Tcl
as a bytearray.
Any value written into the Tcl variable must have the same length as
the underlying storage. Only supported with \fBTcl_LinkArray\fR.
.VE "TIP 312"
.TP
\fBTCL_LINK_SHORT\fR
.
The C variable, or each element of the C array, is of type \fBshort\fR.
Any value written into the Tcl variable must have a proper integer
form acceptable to \fBTcl_GetIntFromObj\fR and be in the range of the
\fBshort\fR datatype; attempts to write non-integer or out-of-range
values into \fIvarName\fR will be rejected with Tcl errors. Incomplete
integer representations (like the empty string, '+', '-' or the
hex/octal/decimal/binary prefix) are accepted as if they are valid too.
.TP
\fBTCL_LINK_USHORT\fR
.
The C variable, or each element of the C array, is of type \fBunsigned short\fR.
Any value written into the Tcl variable must have a proper unsigned
integer form acceptable to \fBTcl_GetIntFromObj\fR and in the
platform's defined range for the \fBunsigned short\fR type; attempts to
write non-integer values (or values outside the range) into
\fIvarName\fR will be rejected with Tcl errors. Incomplete integer
representations (like the empty string, '+', '-' or the hex/octal/decimal/binary
prefix) are accepted as if they are valid too.
.TP
\fBTCL_LINK_LONG\fR
.
The C variable, or each element of the C array, is of type \fBlong\fR.
Any value written into the Tcl variable must have a proper integer
form acceptable to \fBTcl_GetLongFromObj\fR; attempts to write
non-integer or out-of-range
values into \fIvarName\fR will be rejected with Tcl errors. Incomplete
integer representations (like the empty string, '+', '-' or the
hex/octal/decimal/binary prefix) are accepted as if they are valid too.
.TP
\fBTCL_LINK_ULONG\fR
.
The C variable, or each element of the C array, is of type \fBunsigned long\fR.
Any value written into the Tcl variable must have a proper unsigned
integer form acceptable to \fBTcl_GetWideIntFromObj\fR and in the
platform's defined range for the \fBunsigned long\fR type; attempts to
write non-integer values (or values outside the range) into
\fIvarName\fR will be rejected with Tcl errors. Incomplete integer
representations (like the empty string, '+', '-' or the hex/octal/decimal/binary
prefix) are accepted as if they are valid too.
.TP
\fBTCL_LINK_DOUBLE\fR
.
The C variable, or each element of the C array, is of type \fBdouble\fR.
Any value written into the Tcl variable must have a proper real
form acceptable to \fBTcl_GetDoubleFromObj\fR;  attempts to write
non-real values into \fIvarName\fR will be rejected with
Tcl errors. Incomplete integer or real representations (like the
empty string, '.', '+', '-' or the hex/octal/decimal/binary prefix) are
accepted as if they are valid too.
.TP
\fBTCL_LINK_FLOAT\fR
.
The C variable, or each element of the C array, is of type \fBfloat\fR.
Any value written into the Tcl variable must have a proper real
form acceptable to \fBTcl_GetDoubleFromObj\fR and must be within the
range acceptable for a \fBfloat\fR; attempts to
write non-real values (or values outside the range) into
\fIvarName\fR will be rejected with Tcl errors. Incomplete integer
or real representations (like the empty string, '.', '+', '-' or
the hex/octal/decimal/binary prefix) are accepted as if they are valid too.
.TP
\fBTCL_LINK_WIDE_INT\fR
.
The C variable, or each element of the C array, is of type \fBTcl_WideInt\fR
(which is an integer type
at least 64-bits wide on all platforms that can support it.)
Any value written into the Tcl variable must have a proper integer
form acceptable to \fBTcl_GetWideIntFromObj\fR;  attempts to write
non-integer values into \fIvarName\fR will be rejected with
Tcl errors. Incomplete integer representations (like the empty
string, '+', '-' or the hex/octal/decimal/binary prefix) are accepted
as if they are valid too.
.TP
\fBTCL_LINK_WIDE_UINT\fR
.
The C variable, or each element of the C array, is of type \fBTcl_WideUInt\fR
(which is an unsigned integer type at least 64-bits wide on all platforms that
can support it.)
Any value written into the Tcl variable must have a proper unsigned
wideinteger form acceptable to \fBTcl_GetWideUIntFromObj\fR;
attempts to write non-integer values into \fIvarName\fR will be
rejected with Tcl errors. Incomplete integer representations (like
the empty string, '+', '-' or the hex/octal/decimal/binary prefix) are accepted
as if they are valid too.
.TP
\fBTCL_LINK_BOOLEAN\fR
.
The C variable, or each element of the C array, is of type \fBint\fR.
If its value is zero then it will read from Tcl as
.QW 0 ;
otherwise it will read from Tcl as
.QW 1 .
Whenever \fIvarName\fR is
modified, the C variable will be set to a 0 or 1 value.
Any value written into the Tcl variable must have a proper boolean
form acceptable to \fBTcl_GetBooleanFromObj\fR;  attempts to write
non-boolean values into \fIvarName\fR will be rejected with
Tcl errors.
.TP
\fBTCL_LINK_STRING\fR
.
The C variable is of type \fBchar *\fR.
If its value is not NULL then it must be a pointer to a string
allocated with \fBTcl_Alloc\fR.
Whenever the Tcl variable is modified the current C string will be
freed and new memory will be allocated to hold a copy of the variable's
new value.
If the C variable contains a NULL pointer then the Tcl variable
will read as
.QW NULL .
This is only supported by \fBTcl_LinkVar\fR.
.PP
If the \fBTCL_LINK_READ_ONLY\fR flag is present in \fItype\fR then the
variable will be read-only from Tcl, so that its value can only be
changed by modifying the C variable.
Attempts to write the variable from Tcl will be rejected with errors.
.PP
\fBTcl_UnlinkVar\fR removes the link previously set up for the
variable given by \fIvarName\fR.  If there does not exist a link
for \fIvarName\fR then the procedure has no effect.
.PP
\fBTcl_UpdateLinkedVar\fR may be invoked after the C variable has
changed to force the Tcl variable to be updated immediately.
In many cases this procedure is not needed, since any attempt to
read the Tcl variable will return the latest value of the C variable.
However, if a trace has been set on the Tcl variable (such as a
Tk widget that wishes to display the value of the variable), the
trace will not trigger when the C variable has changed.
\fBTcl_UpdateLinkedVar\fR ensures that any traces on the Tcl
variable are invoked.
.PP
Note that, as with any call to a Tcl interpreter, \fBTcl_UpdateLinkedVar\fR
must be called from the same thread that created the interpreter. The safest
mechanism is to ensure that the C variable is only ever updated from the same
thread that created the interpreter (possibly in response to an event posted
with \fBTcl_ThreadQueueEvent\fR), but when it is necessary to update the
variable in a separate thread, it is advised that \fBTcl_AsyncMark\fR be used
to indicate to the thread hosting the interpreter that it is ready to run
\fBTcl_UpdateLinkedVar\fR.
.SH "SEE ALSO"
Tcl_TraceVar(3)
.SH KEYWORDS
boolean, integer, link, read-only, real, string, trace, variable